mcp-rs-cmw500
MCP server that lets AI agents control a Rohde & Schwarz CMW500 radio communication tester via direct TCP/IP SCPI, providing 84 tools for LTE signaling, WLAN, Bluetooth/BLE, and GPRF measurements, with built-in safety limits and a simulator for evaluation.
README
<div align="center">
<img src="assets/logo-banner.svg" alt="mcp-rs-cmw500 — R&S CMW500 radio comms tester — cellular and Wi-Fi compliance" width="100%"/>
<br/>
Drive the Rohde & Schwarz CMW500 Wideband Radio Communication Tester from any MCP-compatible AI client. Direct TCP/IP SCPI (port 5025) — 84 tools across LTE signaling, WLAN, Bluetooth/BLE, and GPRF. No CMWrun dependency.
Quick start · Tools · Workflows · Documentation
</div>
[!IMPORTANT] Hardware required for real measurements. This MCP server controls a real R&S CMW500 Wideband Radio Communication Tester over TCP/IP SCPI. The relevant CMW500 application licenses (LTE / WLAN / Bluetooth / GPRF) must be enabled on the unit for the matching tool surface to do anything.
A simulator is included (
cmw-simulator) so the server can be evaluated and its logic exercised without an instrument. It produces synthetic values only: its*IDN?saysCMW500-SIMULATOR, and every result it produces is markedsimulated. Never report its numbers as measurements.
What is mcp-rs-cmw500?
mcp-rs-cmw500 is a Model Context Protocol
server that automates the R&S CMW500 Wideband Radio Communication Tester
over direct TCP/IP SCPI (port 5025). No CMWrun dependency, no proprietary
middleware — your AI agent talks to the CMW500 the same way a Python script
would, only in natural language.
The server covers five RF technology domains: LTE signaling (cell config, NAS/bearer, C-DRX, full TX measurements), WLAN non-signaling (802.11a/b/g/n/ac/ax with 20/40/80/160 MHz channels), Bluetooth/BLE non-signaling (Classic DH1-DH5 + LE 1M/2M/Coded), GPRF generator/analyzer (CW/ARB output, power/spectrum measurements), and shared signal-path control.
What mcp-rs-cmw500 does well:
- 🤖 AI-native via MCP. First-class Model Context Protocol server with 84 tools across 5 RF technology domains. Any Claude / LLM agent can drive it.
- 🐍 Python + MCP surfaces. Import
rs_cmw500_mcpfor direct driver access, or run as an MCP server for AI-agent automation. - ⚡ Direct SCPI. TCP/IP straight to the CMW500 — no CMWrun, no NI-VISA install, no vendor middleware.
- ✅ Pre-built templates.
lte_tx_power,gprf_power,nonsig_rx,wlan_tx,wlan_rx,ble_tx,ble_rx,bt_classic_tx. - 🔒 AGPL-3.0-or-later. Safety system (power / frequency clamps), SCPI-injection-guarded, raw-SCPI disable flag.
Quick start
Install
git clone https://github.com/RFingAdam/mcp-rs-cmw500.git
cd mcp-rs-cmw500
uv pip install -e ".[dev]"
Configure
cp .env.example .env # edit with your CMW500 IP + safety limits
| Variable | Default | Description |
|---|---|---|
CMW_DEFAULT_HOST |
127.0.0.1 |
CMW500 IP address |
CMW_DEFAULT_PORT |
5025 |
SCPI TCP port |
CMW_MAX_GENERATOR_POWER_DBM |
0 |
Max generator output |
CMW_MAX_EXPECTED_POWER_DBM |
33 |
Max analyzer input |
CMW_MAX_FREQUENCY_HZ |
6e9 |
Upper frequency bound |
CMW_ALLOW_RAW_SCPI |
false |
Enable raw SCPI commands |
Two surfaces, same answer
<table> <tr> <td valign="top" width="50%">
Python
import asyncio
from rs_cmw500_mcp.driver import CMW500Driver
from rs_cmw500_mcp.models.cmw_types import CellConfig
async def main():
async with CMW500Driver("192.168.1.100", 5025) as cmw:
await cmw.lte_configure_cell(
CellConfig(
band=7,
bandwidth_mhz=20,
dl_earfcn=3100,
dl_level_dbm=-70,
)
)
await cmw.lte_cell_on()
# ... wait for UE attach ...
await cmw.lte_meas_configure(stat_count=10)
await cmw.lte_meas_trigger()
results = await cmw.lte_meas_fetch_all()
# Each view is an envelope: check the verdict before the numbers.
power = results["power"]
if power["trustworthy"]:
print(power["values"])
else:
print("no measurement:", power["error"])
asyncio.run(main())
</td> <td valign="top" width="50%">
MCP (Claude Desktop, Claude Code, any MCP client)
{
"mcpServers": {
"rs-cmw500": {
"command": "uv",
"args": [
"--directory", "/path/to/mcp-rs-cmw500",
"run", "rs-cmw500-mcp"
]
}
}
}
Then ask your assistant:
"Bring up a 20 MHz LTE cell on band 7 EARFCN 3100, wait for the UE to attach, then trigger TX power, EVM, ACLR, SEM, and frequency-error measurements."
The agent walks the LTE measurement workflow tool-by-tool and returns the result set.
</td> </tr> </table>
Run
rs-cmw500-mcp # MCP server over stdio
Try it without a CMW500
cmw-simulator --port 5125 --time-scale 0.01 # in one terminal
CMW_DEFAULT_PORT=5125 rs-cmw500-mcp # in another
The simulator parses a real SCPI command tree, keeps a real error queue, and can inject the failures that matter — dropped responses, surplus responses, and specific reliability codes:
cmw-simulator --port 5125 --drop-responses 1 # exercise desync recovery
It binds loopback only unless you pass --allow-remote.
Tools
84 MCP tools, grouped:
| Group | Count | Examples |
|---|---|---|
| Connection | 8 | cmw_discover, cmw_connect, cmw_identify, cmw_get_status, cmw_query_options, cmw_get_errors, cmw_get_capabilities |
| GPRF Generator | 7 | cmw_gen_set_frequency, cmw_gen_set_level, cmw_gen_output_on/off, cmw_gen_load_arb, cmw_gen_configure_arb |
| GPRF Analyzer | 11 | cmw_meas_configure_power, cmw_meas_configure_spectrum, cmw_meas_trigger, cmw_meas_fetch_power, cmw_measure |
| GPRF Signal Path | 4 | cmw_set_signal_path, cmw_get_signal_path, cmw_set_port, cmw_system_all_off |
| RF de-embedding | 2 | cmw_set_external_attenuation, cmw_get_external_attenuation |
| LTE Signaling | 16 | cmw_lte_configure_cell, cmw_lte_cell_on/off, cmw_lte_configure_nas/bearer/cdrx, cmw_lte_meas_* |
| WLAN Non-Signaling | 11 | cmw_wlan_configure, cmw_wlan_set_standard/bandwidth/frequency, cmw_wlan_fetch_* |
| Bluetooth/BLE Non-Signaling | 11 | cmw_bt_configure, cmw_bt_set_technology/ble_mode/packet_type, cmw_bt_fetch_* |
| SCPI | 4 | cmw_scpi_send, cmw_scpi_query, cmw_reset, cmw_preset |
| Templates | 3 | cmw_list_templates, cmw_load_template, cmw_apply_template |
| State | 3 | cmw_save_state, cmw_load_state, cmw_get_full_state |
| Limits | 4 | cmw_define_limit, cmw_check_limits, cmw_list_limits, cmw_clear_limits |
Available templates: lte_tx_power, gprf_power, nonsig_rx, wlan_tx,
wlan_rx, ble_tx, ble_rx, bt_classic_tx. Full tool reference in
docs/tools.md.
What it solves
| Domain | Measurements | Standards |
|---|---|---|
| LTE signaling | Cell setup, NAS attach, bearer, C-DRX, TX power, EVM, ACLR, SEM, frequency error | 3GPP TS 36.521 |
| WLAN non-signaling | 802.11a/b/g/n/ac/ax @ 20/40/80/160 MHz: TX power, EVM, spectrum flatness, frequency error | IEEE 802.11 |
| Bluetooth Classic | DH1-DH5 packet types: TX power, modulation (DEVM), frequency offset/drift | Bluetooth Core 5.x |
| BLE | 1M / 2M / Coded S2 / S8: TX power, modulation, frequency | Bluetooth Core 5.x |
| GPRF | CW/ARB output, power, spectrum — for vendor-specific test sequences | — |
Safety
The server enforces configurable safety limits to protect your equipment:
- Generator power — bounded between
CMW_MIN_GENERATOR_POWER_DBMandCMW_MAX_GENERATOR_POWER_DBM. - Analyzer expected power — bounded by
CMW_MAX_EXPECTED_POWER_DBM. - Frequency range — bounded between
CMW_MIN_FREQUENCY_HZandCMW_MAX_FREQUENCY_HZ. - SCPI sanitization — all parameters validated against injection patterns.
- Raw SCPI off by default — must explicitly set
CMW_ALLOW_RAW_SCPI=true. - Path traversal — state-file paths validated against directory traversal.
Workflows
mcp-rs-cmw500 fits in the following eng-mcp-suite
workflow bundles:
lab-automation— pair withcopper-mountain-vna-mcp,mcp-rs-spectrum-analyzer, andmcp-rs-siggenfor end-to-end RF bench-test workflows driven from a single agent session.cellular-compliance— drive 3GPP TS 36.521 LTE test cases under AI control withmcp-emc-regulationssupplying market-specific limits.
eng-mcp-suite install --workflow lab-automation
Documentation
- 📘 Quick Start — install through first call.
- 🛠️ Tool reference — every MCP tool, every argument.
- 📐 Usage examples — an LTE TX measurement walkthrough.
- 🏗️ Architecture — how this MCP fits in eng-mcp-suite.
- 📝 Changelog
Part of eng-mcp-suite
<sub>This MCP server is part of</sub>
<sub>Part of eng-mcp-suite — an open
umbrella of MCP servers for RF / EMC / PCB / signal-integrity engineering. Drop
into the lab-automation workflow bundle with
eng-mcp-suite install --workflow lab-automation.</sub>
| Domain | Sibling MCPs |
|---|---|
| RF / Transmission lines | lineforge |
| EMC regulatory | mcp-emc-regulations |
| EM simulation | mcp-openems, mcp-nec2-antenna |
| Diagrams | drawio-engineering-mcp |
| Lab gear | copper-mountain-vna-mcp · mcp-rs-spectrum-analyzer · mcp-rs-siggen · mcp-rs-cmw500 |
Contributing
See CONTRIBUTING.md for development guidelines.
uv run pytest tests/ -q # all unit tests (no hardware)
uv run pytest tests/ -m "not integration" -q
ruff check src/ tests/ && ruff format src/ tests/
mypy src/rs_cmw500_mcp/
License
AGPL-3.0-or-later. Relicensed from Apache-2.0 in v0.3.0 to align with the eng-mcp-suite toolkit-wide AGPL move.
Acknowledgments
- Rohde & Schwarz — for the published CMW500 SCPI command reference.
- The MCP working group — for the Model Context Protocol specification.
<div align="center">
<sub>Part of <a href="https://github.com/RFingAdam/eng-mcp-suite">eng-mcp-suite</a> — built for RF engineers, PCB designers, EMC labs, and AI agents.</sub>
</div>
推荐服务器
Baidu Map
百度地图核心API现已全面兼容MCP协议,是国内首家兼容MCP协议的地图服务商。
Playwright MCP Server
一个模型上下文协议服务器,它使大型语言模型能够通过结构化的可访问性快照与网页进行交互,而无需视觉模型或屏幕截图。
Magic Component Platform (MCP)
一个由人工智能驱动的工具,可以从自然语言描述生成现代化的用户界面组件,并与流行的集成开发环境(IDE)集成,从而简化用户界面开发流程。
Audiense Insights MCP Server
通过模型上下文协议启用与 Audiense Insights 账户的交互,从而促进营销洞察和受众数据的提取和分析,包括人口统计信息、行为和影响者互动。
VeyraX
一个单一的 MCP 工具,连接你所有喜爱的工具:Gmail、日历以及其他 40 多个工具。
Kagi MCP Server
一个 MCP 服务器,集成了 Kagi 搜索功能和 Claude AI,使 Claude 能够在回答需要最新信息的问题时执行实时网络搜索。
graphlit-mcp-server
模型上下文协议 (MCP) 服务器实现了 MCP 客户端与 Graphlit 服务之间的集成。 除了网络爬取之外,还可以将任何内容(从 Slack 到 Gmail 再到播客订阅源)导入到 Graphlit 项目中,然后从 MCP 客户端检索相关内容。
e2b-mcp-server
使用 MCP 通过 e2b 运行代码。
Neon MCP Server
用于与 Neon 管理 API 和数据库交互的 MCP 服务器
Exa MCP Server
模型上下文协议(MCP)服务器允许像 Claude 这样的 AI 助手使用 Exa AI 搜索 API 进行网络搜索。这种设置允许 AI 模型以安全和受控的方式获取实时的网络信息。