Siglent SPD1305X MCP server
Drive a Siglent SPD1305X (or any SPD1000X series programmable DC power supply) from Claude Code over Ethernet. No EasyPower, no NI-VISA, no drivers. The supply is an LXI-style instrument that accepts plain SCPI on a raw TCP socket (port 5025); this server wraps that as MCP tools using only the Python standard library, so it runs anywhere Python does.
Tools
| Tool | What it does |
|---|---|
psu_info |
*IDN? + firmware, network config, setpoints, live V/I/P, output state, CV/CC mode, safe limits |
get_measurements |
live measured voltage / current / power at the terminals, plus output state and setpoints |
monitor |
sample V/I/P over a time window: min/max/mean, CV/CC transitions, decimated preview, optional CSV |
set_safety_limits |
declare the safe V/A envelope; required before output can be enabled, and it caps the setpoints |
set_voltage |
program the output voltage setpoint (with readback); guarded (see Safety model) |
set_current |
program the output current limit (with readback); guarded (see Safety model) |
set_output |
enable / disable the physical output (returns resulting state + live measurement) |
save_state |
store present settings into an instrument memory slot (1..5, *SAV) |
recall_state |
recall settings from an instrument memory slot (1..5, *RCL) |
scpi |
raw SCPI escape hatch for anything else |
Safety model (for agents driving the supply)
The control tools are gated so an autonomous agent cannot energize a circuit carelessly:
- Declare limits before energizing.
set_output(True)is refused untilset_safety_limits(max_voltage, max_current)has been called this session. There is no environment default; the agent must consciously commit to a ceiling each time the server starts. - Setpoints are capped. After limits are declared,
set_voltageandset_currentrefuse any value above them. To go higher you must raise the limit on purpose. Enabling the output also re-checks that the present setpoints are within the limits. - No silent live edits. While the output is ON,
set_voltageandset_currentare refused unless you passIKNOWTHEOUTPUTISONDOITANYWAYS=True. The flag is deliberately loud and hard to pass by accident, and it stands out in logs, so a live change to a powered load is always an explicit decision. monitornever changes anything. It only reads, so it is always safe to run.
Setup
Install the one dependency (the MCP SDK):
pip install "mcp[cli]"
...or install the package itself (adds a siglent-mcp console script):
pip install .
Find the supply's IP on the unit under System → LAN, or query it over the
network. This unit is at 192.168.178.209. Confirm the link with:
python -c "import socket; s=socket.create_connection(('192.168.178.209',5025),3); s.sendall(b'*IDN?\n'); print(s.recv(200))"
You should see Siglent Technologies,SPD1305X,....
Register with Claude Code
claude mcp add --env SIGLENT_HOST=192.168.178.209 --scope user siglent -- python D:/ryzzenDL/siglent-mcp/siglent_mcp.py
The
--envflag must have another option (here--scope user) between it and the server name, or the CLI mis-parses the name. Ifpythonisn't on PATH, use the fullpython.exepath or-- cmd /c python D:/....
If you pip installed the package, use the console script instead of a path:
claude mcp add --env SIGLENT_HOST=192.168.178.209 --scope user siglent -- siglent-mcp
Or add it to a .mcp.json (project scope), see .mcp.example.json:
{
"mcpServers": {
"siglent": {
"type": "stdio",
"command": "python",
"args": ["D:/ryzzenDL/siglent-mcp/siglent_mcp.py"],
"env": { "SIGLENT_HOST": "192.168.178.209" }
}
}
}
Then claude mcp list to confirm it connects, and ask Claude things like
"what is the supply outputting right now?", "set it to 5 volts, 0.5 amp limit
and turn the output on", or "read the current and power".
Environment variables
| Var | Default | Meaning |
|---|---|---|
SIGLENT_HOST |
192.168.178.209 |
supply IP |
SIGLENT_PORT |
5025 |
raw SCPI socket port |
SIGLENT_TIMEOUT |
5 |
socket timeout (seconds) |
SIGLENT_CHANNEL |
CH1 |
channel token (the SPD1305X is single channel) |
SIGLENT_VMAX |
30.0 |
hardware voltage ceiling (safe limits and setpoints cannot exceed it) |
SIGLENT_IMAX |
5.0 |
hardware current ceiling (safe limits and setpoints cannot exceed it) |
SIGLENT_OUT_DIR |
./captures |
where monitor writes CSV files |
To reuse this server for a different SPD1000X model, override SIGLENT_VMAX /
SIGLENT_IMAX (for example 16 / 8 for an SPD1168X).
SCPI reference (confirmed on this unit, firmware 2.1.1.9)
| Purpose | SCPI | Notes |
|---|---|---|
| Identity | *IDN? |
Siglent Technologies,SPD1305X,<serial>,<fw>,<hw> |
| Firmware | SYSTem:VERSion? |
|
| Set voltage | CH1:VOLTage 5.000 |
bare VOLTage 5.000 also works |
| Set current limit | CH1:CURRent 0.500 |
bare CURRent 0.500 also works |
| Read voltage setpoint | CH1:VOLTage? |
the programmed value |
| Read current limit | CH1:CURRent? |
|
| Measure output voltage | MEASure:VOLTage? CH1 |
live at the terminals; 0 while output off |
| Measure output current | MEASure:CURRent? CH1 |
|
| Measure output power | MEASure:POWEr? CH1 |
|
| Output on / off | OUTPut CH1,ON / OUTPut CH1,OFF |
write only, there is no OUTPut? query |
| Status register | SYSTem:STATus? |
hex; bit 4 = output ON, bit 0 = CV(0)/CC(1) |
| Error queue | SYSTem:ERRor? |
0 No Error when clean |
| Save / recall | *SAV n / *RCL n |
slot 1..5 |
| Network | IPaddr? MASKaddr? GATEaddr? DHCP? |
Notes / gotchas
- The output state is not queryable directly. There is no
OUTPut?query; readSYSTem:STATus?and test bit 4 (this server does that for you and reportsoutput_on). - CV vs CC comes from bit 0 of
SYSTem:STATus?(0 = constant voltage, 1 = constant current). Under no load the supply sits in CV. - The LAN service is single client and fragile. The port-5025 SCPI server tolerates one connection and can wedge if a client disconnects abruptly or reconnects in a rapid burst; both the raw socket and the VXI-11 service then reset every new client even though the unit still answers ping. This server avoids that by keeping one persistent, lock serialized connection, closing it gracefully, and pacing reconnects. Do not point multiple clients at the supply at once, and do not fire tools concurrently.
- If it does wedge (rare, usually only from an unclean kill), the fix is a power cycle of the unit; ping and the network stack stay up, but the instrument services need the reset. Toggling the output from the front panel is harmless meanwhile.
set_outputenergizes the terminals at the present voltage setpoint. It returns the live measured voltage/current so you can confirm what happened.- Setpoints are independent of output state. Changing voltage/current while the output is off just stages the value; it applies when you enable output.
- The unit powers on with the output off by default (a front panel setting).
Contributing
Issues and PRs welcome, see CONTRIBUTING.md. CI lints with ruff and runs an import smoke test on Python 3.10 to 3.13 (no supply required).
License
MIT © Valentino Saitz
推荐服务器
Baidu Map
百度地图核心API现已全面兼容MCP协议,是国内首家兼容MCP协议的地图服务商。
Playwright MCP Server
一个模型上下文协议服务器,它使大型语言模型能够通过结构化的可访问性快照与网页进行交互,而无需视觉模型或屏幕截图。
Magic Component Platform (MCP)
一个由人工智能驱动的工具,可以从自然语言描述生成现代化的用户界面组件,并与流行的集成开发环境(IDE)集成,从而简化用户界面开发流程。
Audiense Insights MCP Server
通过模型上下文协议启用与 Audiense Insights 账户的交互,从而促进营销洞察和受众数据的提取和分析,包括人口统计信息、行为和影响者互动。
VeyraX
一个单一的 MCP 工具,连接你所有喜爱的工具:Gmail、日历以及其他 40 多个工具。
graphlit-mcp-server
模型上下文协议 (MCP) 服务器实现了 MCP 客户端与 Graphlit 服务之间的集成。 除了网络爬取之外,还可以将任何内容(从 Slack 到 Gmail 再到播客订阅源)导入到 Graphlit 项目中,然后从 MCP 客户端检索相关内容。
Kagi MCP Server
一个 MCP 服务器,集成了 Kagi 搜索功能和 Claude AI,使 Claude 能够在回答需要最新信息的问题时执行实时网络搜索。
e2b-mcp-server
使用 MCP 通过 e2b 运行代码。
Neon MCP Server
用于与 Neon 管理 API 和数据库交互的 MCP 服务器
Exa MCP Server
模型上下文协议(MCP)服务器允许像 Claude 这样的 AI 助手使用 Exa AI 搜索 API 进行网络搜索。这种设置允许 AI 模型以安全和受控的方式获取实时的网络信息。